{"id":7003,"date":"2025-12-19T11:37:49","date_gmt":"2025-12-19T10:37:49","guid":{"rendered":"https:\/\/www.evaporation.com\/?page_id=7003"},"modified":"2026-09-29T12:52:18","modified_gmt":"2026-09-29T10:52:18","slug":"high-temperature-heat-pump-mvr-hybrid-system","status":"publish","type":"page","link":"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/","title":{"rendered":"High-Temperature Heat Pump (HPHT) &#038; MVR"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"7003\" class=\"elementor elementor-7003 elementor-7002\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4f492856 e-con-full e-flex e-con e-parent\" data-id=\"4f492856\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6dc7829a elementor-widget elementor-widget-heading\" data-id=\"6dc7829a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">High-Temperature Heat Pump (HPHT) &amp; MVR<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-11e80274 e-flex e-con-boxed e-con e-parent\" data-id=\"11e80274\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-79e99533 elementor-widget elementor-widget-breadcrumbs\" data-id=\"79e99533\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"breadcrumbs.default\">\n\t\t\t\t\t<p id=\"breadcrumbs\"><span><span><a href=\"https:\/\/www.evaporation.com\/en\/\">Home<\/a><\/span><\/span><\/p>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ce7413d e-con-full e-flex e-con e-child\" data-id=\"ce7413d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-12a01c8c e-con-full e-flex e-con e-child\" data-id=\"12a01c8c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a6b4dc9 elementor-widget elementor-widget-text-editor\" data-id=\"a6b4dc9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>A heat pump captures low-temperature heat (below 60\u00b0C) and raises it to a temperature that is useful for the plant, generally in the form of hot water. At high temperatures, the HPP can supply applications up to a maximum of ~100\u00b0C (demonstrators exist to push this higher depending on the fluid and compressor). <\/p><p><strong>Hybrid heat pump + MVR system<\/strong><\/p><p>For high final temperatures (e.g., 120\u2013200\u00b0C), MVR remains the most efficient option&#8230; but its CAPEX increases with the number of floors. Hybrid architecture consists of letting the heat pump handle the \u201clow\u201d temperature rise (it produces hot water at ~60\u00b0C) and then letting the MVR raise the temperature to higher final temperatures. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c6a0194 e-con-full e-flex e-con e-child\" data-id=\"c6a0194\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4c674b68 elementor-widget elementor-widget-image\" data-id=\"4c674b68\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"56\" height=\"59\" src=\"https:\/\/www.evaporation.com\/wp-content\/uploads\/fe-icon-edge-to-edge.svg\" class=\"attachment-large size-large wp-image-2018\" alt=\"FE Icon\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7116c49f elementor-widget elementor-widget-heading\" data-id=\"7116c49f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hybrid heat pump + MVR system<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-545e6aac elementor-widget elementor-widget-text-editor\" data-id=\"545e6aac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul><li>Fewer MVR floors, <\/li><li>Reduced CAPEX, <\/li><li>High overall COP.<\/li><\/ul><p>On industrial sites, FE units show overall COPs \u202f4 and, on the CMV part alone, double-digit COPs&gt;<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6018fd99 e-con-full e-flex e-con e-child\" data-id=\"6018fd99\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-653b8c92 elementor-widget elementor-widget-image\" data-id=\"653b8c92\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"56\" height=\"59\" src=\"https:\/\/www.evaporation.com\/wp-content\/uploads\/fe-icon-edge-to-edge.svg\" class=\"attachment-large size-large wp-image-2018\" alt=\"FE Icon\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-75c45436 elementor-widget elementor-widget-heading\" data-id=\"75c45436\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">When to choose HTHP alone, MVR alone, or HTHP+ MVR?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c7b372b elementor-widget elementor-widget-text-editor\" data-id=\"c7b372b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>HTHP seule\u202f:<\/p><ul><li>Requirement limited to hot water with temperatures below 100\u00b0C<\/li><li>CAPEX and footprint optimization<\/li><li>Low thermal power (less than 5MW)<\/li><\/ul><p>MVR alone:<\/p><ul><li>Need for steam at \u201chigh\u201d temperatures (above 100\u00b0C)<\/li><li>High thermal power (from 1 MW)<\/li><li>OPEX optimization<\/li><\/ul><p>HTHP + MVR: <\/p><ul><li>High final demand (e.g., 150\u00b0C) with a \u201ccold\u201d source (e.g., 50\u00b0C)<\/li><li>Heat pump for \u201clow\u201d temperatures (fewer MVR stages), <\/li><\/ul><ul><li>MVR for final high pressure<\/li><li>Optimized CAPEX\/OPEX (combination of MVR and HTHP benefits).<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-91d1719 e-con-full e-flex e-con e-child\" data-id=\"91d1719\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8d1f66c elementor-widget elementor-widget-image\" data-id=\"8d1f66c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"56\" height=\"59\" src=\"https:\/\/www.evaporation.com\/wp-content\/uploads\/fe-icon-edge-to-edge.svg\" class=\"attachment-large size-large wp-image-2018\" alt=\"FE Icon\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25a5f67 elementor-widget elementor-widget-heading\" data-id=\"25a5f67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Key engineering points mastered by FE<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8bcef5 elementor-widget elementor-widget-text-editor\" data-id=\"c8bcef5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul><li>Reliability: 30 years of compressor installation and maintenance.<\/li><li>Quality: boiler-quality steam production.<\/li><li>Management: Automation developed internally by FE, daily supervision by FE Service with guaranteed operation and performance.<\/li><li>Engagement de performance : FE s\u2019engage sur les performances des syst\u00e8mes hybrides.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>High-Temperature Heat Pump (HPHT) &amp; MVR A heat pump captures low-temperature heat (below 60\u00b0C) and raises it to a temperature that is useful for the plant, generally in the form of hot water. At high temperatures, the HPP can supply applications up to a maximum of ~100\u00b0C (demonstrators exist to push this higher depending on [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":6071,"menu_order":5,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-7003","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>High-Temperature Heat Pump (HPHT) &amp; MVR - France Evaporation<\/title>\n<meta name=\"description\" content=\"Achieve temperatures of 120 to 200 \u00b0C using a combination of a high-temperature heat pump and a MVR system, with fewer stages and lower CAPEX.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"High-Temperature Heat Pump (HPHT) &amp; MVR - France Evaporation\" \/>\n<meta property=\"og:description\" content=\"Achieve temperatures of 120 to 200 \u00b0C using a combination of a high-temperature heat pump and a MVR system, with fewer stages and lower CAPEX.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/\" \/>\n<meta property=\"og:site_name\" content=\"France Evaporation\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/FranceEvaporation\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-29T10:52:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.evaporation.com\/wp-content\/uploads\/fe-icon-edge-to-edge.svg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/industries\\\/decarbonization\\\/high-temperature-heat-pump-mvr-hybrid-system\\\/\",\"url\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/industries\\\/decarbonization\\\/high-temperature-heat-pump-mvr-hybrid-system\\\/\",\"name\":\"High-Temperature Heat Pump (HPHT) & MVR - France Evaporation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/industries\\\/decarbonization\\\/high-temperature-heat-pump-mvr-hybrid-system\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/industries\\\/decarbonization\\\/high-temperature-heat-pump-mvr-hybrid-system\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.evaporation.com\\\/wp-content\\\/uploads\\\/fe-icon-edge-to-edge.svg\",\"datePublished\":\"2025-12-19T10:37:49+00:00\",\"dateModified\":\"2026-09-29T10:52:18+00:00\",\"description\":\"Achieve temperatures of 120 to 200 \u00b0C using a combination of a high-temperature heat pump and a MVR system, with fewer stages and lower CAPEX.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/industries\\\/decarbonization\\\/high-temperature-heat-pump-mvr-hybrid-system\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.evaporation.com\\\/en\\\/industries\\\/decarbonization\\\/high-temperature-heat-pump-mvr-hybrid-system\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/industries\\\/decarbonization\\\/high-temperature-heat-pump-mvr-hybrid-system\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.evaporation.com\\\/wp-content\\\/uploads\\\/fe-icon-edge-to-edge.svg\",\"contentUrl\":\"https:\\\/\\\/www.evaporation.com\\\/wp-content\\\/uploads\\\/fe-icon-edge-to-edge.svg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/industries\\\/decarbonization\\\/high-temperature-heat-pump-mvr-hybrid-system\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Industries\",\"item\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/industries\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Decarbonization\",\"item\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/industries\\\/decarbonization\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"High-Temperature Heat Pump (HPHT) &#038; MVR\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/\",\"name\":\"France Evaporation\",\"description\":\"Concentr\u00e9 de solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/#organization\",\"name\":\"France Evaporation\",\"url\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.evaporation.com\\\/wp-content\\\/uploads\\\/fe-logo.svg\",\"contentUrl\":\"https:\\\/\\\/www.evaporation.com\\\/wp-content\\\/uploads\\\/fe-logo.svg\",\"width\":131,\"height\":60,\"caption\":\"France Evaporation\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evaporation.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/FranceEvaporation\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/3760850\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@franceevaporation3610\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"High-Temperature Heat Pump (HPHT) & MVR - France Evaporation","description":"Achieve temperatures of 120 to 200 \u00b0C using a combination of a high-temperature heat pump and a MVR system, with fewer stages and lower CAPEX.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/","og_locale":"en_US","og_type":"article","og_title":"High-Temperature Heat Pump (HPHT) & MVR - France Evaporation","og_description":"Achieve temperatures of 120 to 200 \u00b0C using a combination of a high-temperature heat pump and a MVR system, with fewer stages and lower CAPEX.","og_url":"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/","og_site_name":"France Evaporation","article_publisher":"https:\/\/www.facebook.com\/FranceEvaporation","article_modified_time":"2026-09-29T10:52:18+00:00","og_image":[{"url":"https:\/\/www.evaporation.com\/wp-content\/uploads\/fe-icon-edge-to-edge.svg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/","url":"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/","name":"High-Temperature Heat Pump (HPHT) & MVR - France Evaporation","isPartOf":{"@id":"https:\/\/www.evaporation.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/#primaryimage"},"image":{"@id":"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/#primaryimage"},"thumbnailUrl":"https:\/\/www.evaporation.com\/wp-content\/uploads\/fe-icon-edge-to-edge.svg","datePublished":"2025-12-19T10:37:49+00:00","dateModified":"2026-09-29T10:52:18+00:00","description":"Achieve temperatures of 120 to 200 \u00b0C using a combination of a high-temperature heat pump and a MVR system, with fewer stages and lower CAPEX.","breadcrumb":{"@id":"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/#primaryimage","url":"https:\/\/www.evaporation.com\/wp-content\/uploads\/fe-icon-edge-to-edge.svg","contentUrl":"https:\/\/www.evaporation.com\/wp-content\/uploads\/fe-icon-edge-to-edge.svg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/high-temperature-heat-pump-mvr-hybrid-system\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.evaporation.com\/en\/"},{"@type":"ListItem","position":2,"name":"Industries","item":"https:\/\/www.evaporation.com\/en\/industries\/"},{"@type":"ListItem","position":3,"name":"Decarbonization","item":"https:\/\/www.evaporation.com\/en\/industries\/decarbonization\/"},{"@type":"ListItem","position":4,"name":"High-Temperature Heat Pump (HPHT) &#038; MVR"}]},{"@type":"WebSite","@id":"https:\/\/www.evaporation.com\/en\/#website","url":"https:\/\/www.evaporation.com\/en\/","name":"France Evaporation","description":"Concentr\u00e9 de solutions","publisher":{"@id":"https:\/\/www.evaporation.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.evaporation.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.evaporation.com\/en\/#organization","name":"France Evaporation","url":"https:\/\/www.evaporation.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.evaporation.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.evaporation.com\/wp-content\/uploads\/fe-logo.svg","contentUrl":"https:\/\/www.evaporation.com\/wp-content\/uploads\/fe-logo.svg","width":131,"height":60,"caption":"France Evaporation"},"image":{"@id":"https:\/\/www.evaporation.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/FranceEvaporation","https:\/\/www.linkedin.com\/company\/3760850\/","https:\/\/www.youtube.com\/@franceevaporation3610"]}]}},"_links":{"self":[{"href":"https:\/\/www.evaporation.com\/en\/wp-json\/wp\/v2\/pages\/7003","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.evaporation.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.evaporation.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.evaporation.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.evaporation.com\/en\/wp-json\/wp\/v2\/comments?post=7003"}],"version-history":[{"count":23,"href":"https:\/\/www.evaporation.com\/en\/wp-json\/wp\/v2\/pages\/7003\/revisions"}],"predecessor-version":[{"id":9430,"href":"https:\/\/www.evaporation.com\/en\/wp-json\/wp\/v2\/pages\/7003\/revisions\/9430"}],"up":[{"embeddable":true,"href":"https:\/\/www.evaporation.com\/en\/wp-json\/wp\/v2\/pages\/6071"}],"wp:attachment":[{"href":"https:\/\/www.evaporation.com\/en\/wp-json\/wp\/v2\/media?parent=7003"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}